A lot of Winter Park outlets sit in plaster walls on circuits that never had a ground. That decides what we can put in the box and how carefully it has to come out.
Per-device pricing drops steeply with count. A whole-house refresh is far cheaper per outlet than a single service call, and there is one trip charge instead of six.
If you could swap the city name out of this page and it would still be accurate, it should not exist. Here is what actually changes here.
Older homes here often have small metal boxes set in plaster and lath. A modern GFCI is bulky, and forcing it in cracks plaster. We check box depth before we promise a device, and tell you where a box needs replacing.
Someone may have already put three-prong outlets on an ungrounded circuit. It looks updated and it is not. We test each one. Where there is no ground, the code-compliant fix short of a rewire is GFCI protection labeled "No equipment ground."
Decades of repainting leave plates and devices sealed in paint, sometimes into the slots. Those contacts do not grip well. They are cheap to replace, and in quantity standard devices run $25 to $45 each.
The newer homes on the lakes are a different job: exterior and dock outlets that need GFCI protection, weather-resistant devices and in-use covers. GFCI devices run $65 to $95 each. A new dock or patio outlet is permitted through the City of Winter Park.
Same ranges we publish everywhere, because the work does not cost more just because of the zip code. You get an exact number at the free estimate.
Mike is in Winter Park most Tuesdays. You will have a name and a text before anyone is at your door.
"Grant wired our new kitchen project. We have used him two other times and plan on using him with our next project."
"…In Phaze sent 3 people for the job, which they completed in 1 day, even vacuuming up afterwards."
"After getting the run around from other electricians I came across In Phase. Wish I found them first."
"Unlike some of their competitors, they don't try to up-sell products that aren't strictly necessary."
People do, and a fair share of our repair calls are fixing the results — reversed polarity, a bootleg ground jumper, a backstab connection that failed. It is cheap work for us to do right.
Jumping neutral to ground inside the box so a tester shows "grounded." It passes a cheap tester and it is genuinely dangerous. We find these constantly in Central Florida.
Not legally, but they cannot safely serve modern electronics. Where there is no ground, GFCI protection with the correct label is the code-compliant path short of a rewire.
Kitchens, bathrooms, garages, unfinished basements, exterior, laundry areas and anywhere near a pool or spa. If yours are missing, that is worth fixing.
Considerably. One trip, one setup, volume pricing per device. Doing them one at a time as they fail is the expensive way.
Yes. Worth noting USB modules age faster than the outlet does — we will tell you where they make sense.
Free estimate. If you do not need the work, we will tell you — which is why people in Winter Park call us back years later.